Let's start with a video, below is a clip of a subxiphoid view of the heart. There are several things to note in this clip from a quality assurance perspective:
1. Are these images adequate? To determine this, answer the questions below:
a. Is the correct probe used?
b. Is the correct exam type used?
c. Is the depth set properly
d. Is the image centered on screen?
e. Is the complete organ visible?
f. Is the gain set correctly?
g. Is the image labeled correctly?
2. Can the correct diagnosis be made from this clip?
3. If so, what is the correct diagnosis?
4. What could the sonologist do to improve the visualization of the heart?
QA #1 from UF-Jax Emergency Medicine on Vimeo.
So let's look at this video clip critically and answer each of these QA points.
1. The sonologist used the correct probe for a cardiac scan (phased arrray) and had the correct exam type selected (cardiac). Although the heart is centered on the screen, the depth is set at only 16 cm (depending on the patient's girth, 21-26cm is usual). You will note that the posterior portion of the heart appears to be cut off. This is a really big problem if you are evaluating the heart for an effusion. You expect that the fluid will collect first in the most dependant portion of the pericardium- posteriorly in a supine patient. If you cut off the posterior wall of the heart, you may be unable to determine if there is an effusion present or not. Therefore, in this video clip, the complete organ is not visible. The gain is set perfectly and allows for the fluid filled portions of the heart to appear anechoic or black, while the myocardium stands out starkly more white or hyperechoic. By not over-gaining this image, we can determine that there are no visible clots in the heart which would appear as echogenic foci (grey areas). The clip is adequately labeled so that others not present at the time of the exam can know what the sonologist intended to image.
2. The diagnosis can be made by this clip, but it is a little subtle. Note that the left ventricle is located at the bottom right in the clip. As the ventricle contracts, a thin sliver of fluid in the pericardium can be visualized. Do not be fooled by only looking anteriorly, as the pericardial fat pad can mimic an effusion. The fat pad will appear as an anechoic stripe in the near screen on the parasternal long axis view (PSLX), anterior to the right ventricle. Without an anechoic stripe in the posterior pericardium, the diagnosis of an effusion cannot be made.
3. Correct diagnosis: Pericardial effusion. It is difficult to determine if tamponade is present from this view, but the right ventricle appears to move symmetrically. Pericardial tamponade can be diagnosed on ultrasound by the presence of right ventricular (RV) collapse. This can easily be seen using the PSLX view. The RV is located in the near field and the wall will collapse inward with each contraction. It will look like someone has placed their finger on the RV and pushed in toward to the septum at that one point. Always look for tamponade on any patient with an effusion. Usually it is the small, new effusions that will cause tamponade since the pericardium has not been stretched out to accommodate the fluid collection.
4. The sonologist did a fair job in this clip, but would really make the clip better by increasing the depth of field to allow the heart and pericardium to be completely visualized. Otherwise, good job!